LIFTING AND WRINKLING

Raising the layers of the existing coating. The defect occurs during application of a new coat or while coat drying.

Causes
  • applying too thick layers of coat,
  • insufficiently dried existing coating,
  • too small thickness of the insulation coat,
  • too long evaporation time during the work with two-component products in the „wet on wet system”.
Prevention
  • the observance of evaporation times,
  • compliance with the recommendations of technical documentation concerning the application of insulator,
  • make solvent test.
Repair
Sand to a healthy layer. Perform a repair using the correct coat and primer.

We use cookies for statistical purposes (Google Analytics). You can block our cookies by changing your browser settings Cookies Policy.