OVERSPRAY

Very small fog particulates present on the surface of top coating.

Causes
  • wrong choice of thinners for the conditions of application,
  • insufficient protection of noncoated surface areas,
  • poor functioning of coating cabin.
Prevention
  • use hardener and solvent in accordance with actual temperature and the size of the coated object,
  • carefully protect noncoated areas,
  • ensure appropriate ventilation inside the coating cabin.
Repair
Mat and polish.
 